Design Conditions

  • Design ambient temperature (min/max): 9°C/50°C
  • Design relative humidity: 100%
  • Altitude: sea level
  • Atmosphere: outdoor, offshore, corrosive, marine, sand storm dust and salty environment
  • Hazardous area classification: Class 1, Zone 2, Gas group IIB

Scope of supply

Umm Lulu Full Field Development Project

  • N. 6 Customized A60 Pressurized Containerized Solution for CAT C18

Building Features

Container features:

  • Dimensions: l. 7000; w. 3000; h. 3300 mm
  • Weight (with installed equipment): 15.500 kg
  • IP54 protection
  • Passive fire resistance: A60 as per SOLAS-74 regulations
  • Noise reduction: up to 85 dB(A) at 1 m

Generator’s auxiliaries supplied by SITAL:

  • Batteries, battery box and change over facility (installed inside the container)
  • Fire and Gas detection and fighting system suitable for hazardous area (bottles will be installed outside the container into a dedicated canopy)
  • Unit Control Panel (UCP, installed outside the container)
  • Motor Control Panel (MCP installed inside the container in Hazardous area)
  • Local Control Panel (LCP installed inside the container)
  • Engine Driven Cooling Radiator
  • Exhaust Heat Exchanger

Documentation:

  • Engineering for the developing of wiring diagrams, P&IDs and all others packaging documentation has been prepared in cooperation between Sital and Customer
  • ATEX Zone 2 with 3rd party certification

Gallery

Gas cooler

Cooling system

Fire & gas detection and suppression

Hydraulic connections

Electrical System and electrical connections