Main features
With the strong development of the electric drive car in the automotive sector, the market demand for containers suitable to host testing activities is growing, and in particular:
SITAL is able to offer containers complete with low and high temperature air conditioning systems, sized in relation to the different testing needs. There is also povided a safety system in compliance with the hazard levels defined by the EUCAR consortium, as per opposite table.
The containerized walk in climatic chambers relized by SITAL are particularly suitable for outdoor installations and are provided with CE certification according to the Machinery
Hazard Level | Description | Criteria for Severity Classification & Effects |
---|---|---|
0 |
No Effect |
No effect. No loss of functionality |
1 |
Reversible Loss of Function |
No defect; no leakage; no venting, fire, or flame; no rupture; no explosion; no exothermic reaction or thermal runaway. Temporary loss of battery functionally. Resetting of protective device needed. |
2 |
Irreversible defect/damage |
No leakage; no venting, fire, or flame; no rupture; no explosion; no exothermic reaction or thermal runaway. RESS irreversibly damage. Repair needed. |
3 |
Leakage Δ mass < 50% |
No venting, fire, or flame; no rupture; no explosion. Weight loss < 50% of electrolyte weight. Light smoke (electrolyte=solvent+salt). |
4 |
Leakage Δ mass ≥ 50% Fire or Flame |
No fire or flame; no rupture; no explosion. Weight loss ≥ 50% of electrolyte weight. Heavy smoke (electrolyte=solvent+salt). |
5 |
Fire or Flame |
No rupture; no explosion (i.e. no flying parts) |
6 |
Rupture |
No explosion. RESS could disintegrate but slowly without flying parts of high thermal or kinetic energy. |
7 |
Explosion |
Explosion (i.e. disintegration of the RESS with externally damaging thermal & kinetic forces). Exposure to toxic substances in excess of OSHA limits. |
Directive and REI 120 certification. In particular, SITAL uses its own production doors, opportunely designed in order to ensure the double requirement:
It is possible to use treatments or materials suitable for resisting the corrosive actions of internal and external agents:
SOME EXAMPLES OF OUR JOBS
CONTAINERIZED CLIMATIC WALK-IN CHAMBER FOR AUTOMOTIVE BATTERY TEST made by double climatic chamber and technical room. The container is suitable for Hazard Level 5 and is complete of:
-
- Flooding pool for immersion of battery in case of fire event, with purpose to limit the temperature rise in the same, so preventing the fire regeneration.
- REI 120 passive fire protection of wall and roof
- REI 120 door (design specifically developed for both fire resistance and negative temperature operation)
- Lighting system suitable for operate in low temperature conditions
CONTAINERIZED CLIMATIC WALK-IN CHAMBER FOR ELECTRIC VEHICLES TESTS, consisting of a single climatic chamber and technical room. The container is suitable for Hazard Level 5 and is complete with:
CONTAINER FOR AUTOTRACTION BATTERY STORAGE FOR AND STORAGE TESTS, composed of climatic chamber and technical room. The container is complete with: